The OMC-1 Ambient Ozone Monitor & Controller is specially designed for continuous real-time detecting and monitoring of ambient ozone in the air.
Operating Principle of Custom Indoor Air Quality Detection
The Electrochemical sensor use electrolytes and electrodes to measure ozone presence. When ozone comes into contact with the electrolytes in the device, it interacts with electrolytes. This causes electrons to start passing between the two electrodes, triggering the device. The sensor works very quickly. Turn ON the power, the LCD display activated in green. The measured temperature and the relative humidity displays on the upper line of the LCD and the second line is the ozone level.
The OMC-1 Ambient Ozone Monitor & Controller is very essential in detecting any ozone leakage from ozone systems placed in indoors. It is made up of high grade aluminium powder coated with wall mount access that can be easily attached to an ozone system. It measures the amount of ozone in the air from 0 to 5000 ppb concentrations up to 5 ppm. It has LCD display with three colour backlights (Green/Yellow/Red).
Turn ON the power, the LCD display activated in green. The measured temperature and the relative humidity displays on the upper line of the LCD and the second line is the ozone level.
- Specially designed for detecting indoor ambiance quality
- Modbus RS-485 communication interface
- Buzzer alarm and three colour backlight LCD indication
- Provide 2x relay dry contact outputs and 1x analog output
- Multiple application, wall mounting type
- Temperature and Humidity measurement in the display
Indoor ambiance quality
Plasma sterilization cycles are generally faster compared to other low-temperature sterilization methods like ethylene oxide (EtO)
Effective Sterilization
Plasma sterilization is highly effective in eliminating a wide range of microorganisms, including bacteria, viruses, fungi, and spores.
Low Toxicity
Plasma sterilization processes have lower toxicity compared to some other chemical sterilization methods, enhancing safety for both patients and healthcare workers.
Quality Assurance
Many plasma sterilizers are equipped with monitoring and documentation systems that provide detailed information on the sterilization process, ensuring quality control
Flexibility
They offer flexibility in terms of the types of items that can be sterilized, making them suitable for a variety of healthcare and research applications.
Minimal Residue
The process leaves minimal residue, and any residue left behind is typically non-toxic and easily removed during aeration, ensuring that sterilized items are safe for use.
Technical Specifications
Model | OMC-1 |
---|---|
Input Power | 24 VAC / VDC |
Power Consumption | 2.8 Watts |
Ozone Measurement | 0-5000 ppb (0-5 ppm) |
Display Resolution | 1 ppb (0.001 ppm) |
Warm Up Time | < 60 seconds |
Temperature Measurement | 5°C to 60°C |
Humidity Measurement | 0 ~ 80% RH |
Sensing Element | Electrochemical Sensor |
Temperature Sensor | NTC 5k thermistance / HS series capacitive |
LCD Backlight | Green – Normal Yellow – First stage alarm Red – Second stage alarm |
Sound Alarm | Buzzer alarm and Red backlight |
Working condition / Storage conditions | 5°C – 35°C (41°F ~ 95°F) / 0 ~ 80% RH |
Material of Construction | Aluminium powder coated |
Dimension (LxWxH) | 102.6 x 36.3 x 155 mm |